FINERACT-1471: AsciiDoc extension for read/write/batch separation
This commit is contained in:
committed by
Arnold Gálovics
parent
235dfa8738
commit
a89fe53937
@@ -8,6 +8,8 @@ include::local.adoc[leveloffset=+1]
|
||||
|
||||
include::appserver.adoc[leveloffset=+1]
|
||||
|
||||
include::instance-type.adoc[leveloffset=+1]
|
||||
|
||||
include::kubernetes.adoc[leveloffset=+1]
|
||||
|
||||
include::aws.adoc[leveloffset=+1]
|
||||
|
||||
@@ -0,0 +1,177 @@
|
||||
= Fineract Instance types
|
||||
|
||||
In cases where Fineract has to deal with high load, it can cause a performance problem for a single Fineract instance.
|
||||
To overcome this problem, Fineract instances can be started in different instance types for better scalability and performance in a multi-instance environment:
|
||||
|
||||
.Fineract instance types
|
||||
* Read instance
|
||||
* Write instance
|
||||
* Batch instance
|
||||
|
||||
Each instance type comes with different restrictions. The specifics can be found in the table below.
|
||||
|
||||
.Instance types
|
||||
|===
|
||||
^| ^| Read instance ^| Write instance ^| Batch instance
|
||||
|
||||
| Using only read-only DB connection | Yes | No | No
|
||||
| Batch jobs are automatically scheduled or startable via API | No | No | Yes
|
||||
| Can receive events (business events, hook template events) | No | Yes | No
|
||||
| Can send events (business events, hook template events) | No | Yes | Yes
|
||||
| Read APIs supported | Yes | Yes | No
|
||||
| Write APIs supported | No | Yes | No
|
||||
| Batch job APIs supported | No | No | Yes
|
||||
| Liquibase migration initiated upon startup | No | Yes |No
|
||||
|===
|
||||
|
||||
== Configuring instance types in single instance setup
|
||||
|
||||
If Fineract is running as a single instance, then all of the 3 instance types should be enabled. In this case, there is no need to worry about the configuration, because this is the default behavior.
|
||||
|
||||
[ditaa, target="single-instance-diagram"]
|
||||
----
|
||||
+---------+
|
||||
| |
|
||||
| Read |
|
||||
| Write |
|
||||
| Batch |
|
||||
| |
|
||||
+----+----+
|
||||
|
|
||||
v
|
||||
+----------------+
|
||||
|{s} |
|
||||
| Fineract DB |
|
||||
| |
|
||||
+----------------+
|
||||
----
|
||||
|
||||
== Configuring instance types in multi-instance setup
|
||||
|
||||
A common solution to dealing with the high load is to deploy 1 write and 1 batch instances and deploy multiple read instances with read replicas of the Fineract database.
|
||||
In this case, the write instance and the database will be freed from part of the load, because read request will use the separated read instance and its read replica database.
|
||||
|
||||
[ditaa, target="multiple-read-instances-diagram"]
|
||||
----
|
||||
+---------+ +---------+ +---------+ +---------+
|
||||
| | | | | | | |
|
||||
| | | | | | | |
|
||||
| Write | | Batch | | Read | [...] | Read |
|
||||
| | | | | | | |
|
||||
| | | | | | | |
|
||||
+----+----+ +----+----+ +----+----+ +----+----+
|
||||
| | | |
|
||||
+-------+--------+ | |
|
||||
| | |
|
||||
v v v
|
||||
+----------------+ +-------------+ +-------------+
|
||||
|{s} | |{s} | |{s} |
|
||||
| Fineract DB +-=----->+ Read |[...]| Read |
|
||||
| | | Replica | | Replica |
|
||||
+----------------+ +-------------+ +-------------+
|
||||
| ^
|
||||
| |
|
||||
+-----=-------------------------------------+
|
||||
----
|
||||
|
||||
Also a common scenario when Close of Business jobs are running and Fineract has to deal with a high amount of processes.
|
||||
(In a future release) Fineract (will be) is able to run this CoB jobs in batches.
|
||||
In multi-instances environment these CoB jobs can run on multiple batch instances and they don't have any impact on the performance of the read and write processes.
|
||||
The best practice is to deploy 1 master batch instance and multiple worker batch instances.
|
||||
|
||||
[ditaa, target="multiple-batch-instances-diagram"]
|
||||
----
|
||||
+---------+ +---------+ +---------+ +---------+ +---------+
|
||||
| | | | | | | | | |
|
||||
| | | | | | | | | |
|
||||
| Read | | Write | | Batch | | Batch | [...] | Batch |
|
||||
| | | | | Manager | | Worker | | Worker |
|
||||
| | | | | | | | | |
|
||||
+----+----+ +----+----+ +----+----+ +----+----+ +----+----+
|
||||
| | | | |
|
||||
+----------------+---------------+-----------------+-------------------+
|
||||
|
|
||||
v
|
||||
+----------------+
|
||||
|{s} |
|
||||
| Fineract DB |
|
||||
| |
|
||||
+----------------+
|
||||
----
|
||||
These soultions can be mixed with each other, based on the load of the Fineract deployment.
|
||||
|
||||
== Configuring instance type via environment variables
|
||||
|
||||
The Fineract instance type is configurable via environment variables for the following 3 values:
|
||||
|
||||
.Environment variables
|
||||
|===
|
||||
^| Instance type ^| Environment variable
|
||||
|
||||
| Read instance | FINERACT_READ_MODE_ENABLED
|
||||
| Write instance | FINERACT_WRITE_MODE_ENABLED
|
||||
| Batch instance | FINERACT_BATCH_MODE_ENABLED
|
||||
|===
|
||||
|
||||
The environment variable values are booleans (true/false). The Fineract instance can be configured in any combination of these instance types, although if all 3 configurations are false, startup will fail. The default value for all 3 values is true.
|
||||
|
||||
The configured Fineract instance types are easily accessible via a single Spring bean, named `FineractProperties.FineractModeProperties` that has 4 methods: `isReadMode()`, `isWriteMode()`, `isBatchMode()`, `isReadOnlyMode()`
|
||||
|
||||
== Liquibase Database Migration
|
||||
|
||||
Liquibase data migration is allowed only for write instances
|
||||
|
||||
== APIs
|
||||
|
||||
=== Read APIs are allowed only for read and write instances
|
||||
|
||||
A Fineract instance is ONLY able to serve read API calls when it’s configured as a read or write instance. In batch instance mode, it won’t serve read API calls.
|
||||
If it’s a read or write instance, the read APIs will be served.
|
||||
If it’s a batch instance, the read APIs won't be served and a proper HTTP status code will be returned.
|
||||
The distinction whether something is a read API can be decided based on the HTTP request method. If it’s a GET, we can assume it’s a read call.
|
||||
|
||||
=== Write APIs are allowed only for write instances
|
||||
|
||||
A Fineract instance is ONLY able to serve write API calls when it’s configured as a write instance. In read or batch instance mode, it won't serve write API calls.
|
||||
If the write APIs won't be served and a proper HTTP status code will be returned.
|
||||
If it’s a write instance, the write APIs will be served except the ones related to batch jobs.
|
||||
The distinction whether something is a write API can be decided based on the HTTP request method. If it’s non-GET, we can assume it’s a write call. Also, the write APIs related to batch jobs (starting/stopping jobs) will not be served either.
|
||||
|
||||
=== Batch job APIs are allowed only for batch instances
|
||||
|
||||
A Fineract instance is ONLY able to serve batch API calls when it’s configured as a batch instance. In read or write instance mode, it won’t serve batch API calls.
|
||||
If the batch APIs won't be served and and a proper HTTP status code will be returned.
|
||||
If it’s a batch instance, the batch APIs will be served.
|
||||
|
||||
== Batch jobs
|
||||
|
||||
=== Batch job scheduling is allowed only for batch instances
|
||||
|
||||
Batch jobs are scheduled only if the Fineract instance running as a batch instance
|
||||
|
||||
|
||||
== Read-only instance type restrictions
|
||||
|
||||
If the read mode is enabled, but the write mode and batch mode are disabled, Fineract instance runs in read-only mode.
|
||||
|
||||
=== Events are disabled for read-only instances
|
||||
|
||||
When a Fineract instance is running in read-only mode, all event receiving/sending will be disabled.
|
||||
|
||||
=== Read-only tenant connection support
|
||||
|
||||
With read separation, there’s a possibility to use read-only database connections for read-only instances.
|
||||
If the instance is read-only , the DataSource connection used for the tenant will be read-only.
|
||||
If the instance is read-only and the configuration for the read-only datasource is not set, the application startup will fail.
|
||||
|
||||
== Batch-only instance type restrictions
|
||||
|
||||
If the batch mode is enabled, but the read mode and write mode are disabled, Fineract instance runs in batch-only mode.
|
||||
|
||||
=== Receiving events is disabled for batch-only instances
|
||||
|
||||
When a Fineract instance is running as batch, event receiving will be disabled while sending events will be still possible since the batch jobs are potentially generating business events.
|
||||
|
||||
|
||||
|
||||
|
||||